"IntendedFor": "func/sub-07_task-MID_bold.nii.gz",
|
|
"Modality": "MR",
|
|
"MagneticFieldStrength": 3,
|
|
"ImagingFrequency": 123.239,
|
|
"Manufacturer": "Siemens",
|
|
"ManufacturersModelName": "MAGNETOM Prisma Fit",
|
|
"InstitutionName": "Instytut Biologii Doswiadczalnej",
|
|
"InstitutionAddress": "Pasteura 3,Warszawa,District,PL,02093",
|
|
"DeviceSerialNumber": "167119",
|
|
"StationName": "AWP167119",
|
|
"BodyPartExamined": "BRAIN",
|
|
"PatientPosition": "HFS",
|
|
"ProcedureStepDescription": "Head32$ PS23a",
|
|
"SoftwareVersions": "syngo MR XA30",
|
|
"MRAcquisitionType": "2D",
|
|
"SeriesDescription": "SpinEchoFieldMap_mid_AP",
|
|
"ProtocolName": "SpinEchoFieldMap_mid_AP",
|
|
"ScanningSequence": "EP",
|
|
"SequenceVariant": "SK",
|
|
"ScanOptions": "FS",
|
|
"PulseSequenceName": "epse2d1_82",
|
|
"ImageType": [
|
|
"ORIGINAL",
|
|
"PRIMARY",
|
|
"FMRI",
|
|
"NONE"
|
|
],
|
|
"ImageTypeText": [
|
|
"ORIGINAL",
|
|
"PRIMARY",
|
|
"M",
|
|
"ND",
|
|
"NORM"
|
|
],
|
|
"NonlinearGradientCorrection": false,
|
|
"SeriesNumber": 6,
|
|
"AcquisitionTime": "16:16:6.100000",
|
|
"AcquisitionNumber": 1,
|
|
"SliceThickness": 2.5,
|
|
"SpacingBetweenSlices": 2.5,
|
|
"EchoTime": 0.066,
|
|
"RepetitionTime": 8,
|
|
"MTState": false,
|
|
"FlipAngle": 90,
|
|
"PartialFourier": 1,
|
|
"BaseResolution": 84,
|
|
"ShimSetting": [
|
|
3070,
|
|
-11574,
|
|
6686,
|
|
378,
|
|
40,
|
|
-103,
|
|
-72,
|
|
-43
|
|
],
|
|
"TxRefAmp": 260.953,
|
|
"PhaseResolution": 1,
|
|
"VendorReportedEchoSpacing": 0.00058,
|
|
"ReceiveCoilName": "Head_32",
|
|
"ReceiveCoilActiveElements": "HEA;HEP",
|
|
"CoilString": "Head_32",
|
|
"PulseSequenceDetails": "%CustomerSeq%\\cmrr_mbep2d_se",
|
|
"WipMemBlock": "f219a99a-b14f-4cd2-9b68-c15f5356728b||Sequence: R017 nxva30a/master r/e4e260217; Mar 27 2023 20:12:45 by eja",
|
|
"CoilCombinationMethod": "Sum of Squares",
|
|
"MatrixCoilMode": "SENSE",
|
|
"PercentPhaseFOV": 97.619,
|
|
"PercentSampling": 100,
|
|
"EchoTrainLength": 82,
|
|
"AcquisitionMatrixPE": 82,
|
|
"ReconMatrixPE": 82,
|
|
"BandwidthPerPixelPhaseEncode": 21.026,
|
|
"EffectiveEchoSpacing": 0.000580002,
|
|
"DerivedVendorReportedEchoSpacing": 0.000580002,
|
|
"TotalReadoutTime": 0.0469802,
|
|
"PixelBandwidth": 2289,
|
|
"DwellTime": 2.6e-06,
|
|
"PhaseEncodingDirection": "j-",
|
|
"SliceTiming": [
|
|
3.99,
|
|
0,
|
|
4.125,
|
|
0.135,
|
|
4.2575,
|
|
0.2675,
|
|
4.39,
|
|
0.4,
|
|
4.5225,
|
|
0.5325,
|
|
4.655,
|
|
0.665,
|
|
4.79,
|
|
0.8,
|
|
4.9225,
|
|
0.9325,
|
|
5.055,
|
|
1.065,
|
|
5.1875,
|
|
1.1975,
|
|
5.32,
|
|
1.33,
|
|
5.455,
|
|
1.465,
|
|
5.5875,
|
|
1.5975,
|
|
5.72,
|
|
1.73,
|
|
5.8525,
|
|
1.8625,
|
|
5.985,
|
|
1.995,
|
|
6.12,
|
|
2.13,
|
|
6.2525,
|
|
2.2625,
|
|
6.385,
|
|
2.395,
|
|
6.5175,
|
|
2.5275,
|
|
6.65,
|
|
2.66,
|
|
6.7825,
|
|
2.795,
|
|
6.9175,
|
|
2.9275,
|
|
7.05,
|
|
3.06,
|
|
7.1825,
|
|
3.1925,
|
|
7.315,
|
|
3.325,
|
|
7.4475,
|
|
3.46,
|
|
7.5825,
|
|
3.5925,
|
|
7.715,
|
|
3.725,
|
|
7.8475,
|
|
3.8575
|
|
],
|
|
"ImageOrientationPatientDICOM": [
|
|
0.999577,
|
|
-0.0215978,
|
|
0.019487,
|
|
0.0223346,
|
|
0.999012,
|
|
-0.03842
|
|
],
|
|
"InPlanePhaseEncodingDirectionDICOM": "COL",
|
|
"ConversionSoftware": "dcm2niix",
|
|
"ConversionSoftwareVersion": "v1.0.20220720"
|
|
} |